ایکالر

Semi-gloss alkyd surface paint

E-color alkyd (oil) surface paint is a single component and is prepared on the basis of reinforced alkyd resin. This paint is prepared according to the technical specifications of IPS-M-TP-130 standard. The hardening mechanism is the result of oxidation and solvent jumping.

[print_button_en]
رنگ رویه آلکیدی نیمه براق​

Description of nano traffic color

Its properties include:
  1. Very smooth, even and impermeable surface
  2. Very good brightness and effect
  3. Good abrasion resistance
  4. Water and moisture resistant
  5. Excellent resistance to ultraviolet radiation of the sun
  6. Oils resistant to fuels
  7. Very fast drying speed
  8. has very good self-cleaning capability
  9. Excellent adhesion to asphalt and concrete
  10. Excellent adhesion and durability
  11. Can be used and executed with marking machines
  12. Usability in different climatic zones
  13. Can be used with glass bits

Uses

This color is widely used for marking and marking roads and passages, including its uses are:
  • Roads and highways
  • Airport runway markings
  • Urban thoroughfares
  • Urban bookmarks
  • Marking halls and parking lots
  • Painting floors and walls of halls and parking lots

Technical specifications

فام Traffic white – Traffic yellow – Other shades
Volume solid percentage 58 ± 2
Storage time one year
Recommended thickness 100 to 400 microns
Density 05, 0 ± 1.25
350 micron theory coverage 1.2 square meters per kilogram

Drying and coating conditions

Drying time Next layer application time
Temperature surface depth Complete hardening minimum Maximum Notes
25 ° C 1 hour 10 hours 2 days 6 hours 7 days Other factors such as the thickness of the color film and temperature changes, etc. affect the drying time.

Terms and equipment of application

Thinner Traffic thinner
Application temperature 5 to 50 degrees Celsius
Maximum relative humidity 80%
Surface temperature 3 to 5 degrees above the dew point
Application method Air spray. Airless spray, brush and roll
Application conditions Ordinary spray Airless spray brush Roll
Percent solvent 5-10% 3-5% 3-7% 4-8%
head pressure 2 -5 times 140 – 160 bar
Nozzle head diameter 1.2 to 1.8 mm 0.3 to 0.5 mm
hand distance 30-50 cm 40-60 cm

Surface preparation

Painted surfaces – These surfaces must be completely clean and free of any grease and other contaminants. Before painting the surface must be perfect Dry and if a long time has passed since the application of the undercoat, a suitable roughness should be created by soft sanding on the surface. Steel surfaces – Wash the steel surface thoroughly to remove grease, salt and any other contaminants. De-ring and create Profiles on surfaces by various methods such as ballast document up to 2.5 degrees Swedish SA or by mechanical tools up to ST3-ISO degree (SP10-SSPC). In metal structures and welded points and corners should be smooth and polished and free of any appendages and sharpness. After de-rusting and creating the profile of the particles obtained from the preparation and other contaminants, remove the surface with moisture and grease free from moisture and grease by vacuum method. Note that the application of the first layer (primer) should be done no later than two hours after preparation.

Staining instructions

After preparing the surface and choosing the method of painting, first mix the fabric of the relevant solution with the recommended ratio and mix the mixture thoroughly to make it uniform. Add a special amount of ethyl silicate thinner if needed (usually not needed) (add to the mixture and stir until a primer is applied, then apply the paint with a suitable tool.

Storage and transportation

The above color was flammable

Description of semi-gloss alkyd surface paint

Its properties include:
  1. Good abrasion resistance
  2. Possibility of operation up to zero temperature
  3. Water and moisture resistant
  4. Resistance to oils and petroleum products
  5. Easy and fast implementation
  6. Excellent adhesion to concrete and masonry and metal surfaces
  7. Create an integrated and flooded surface
  8. Proper corrosion resistance

Indications This paint is used as a top and middle layer for systems with moderate and good capabilities in terms of corrosion, and due to the price and easy to use conditions, it achieves special capabilities, including its uses include:
  • Decorative building colors
  • Marine Industries
  • Pipelines and steel and concrete structures
  • Refineries, power plants and chemical plants
  • Concrete surfaces
  • To mark

Technical specifications

فام in different shades
Volume solid percentage 55 ± 2
Storage time one year
Recommended thickness 50 to 100 microns
Density 05, 0 ± 1.25
Theoretical coverage of 50 microns per kilogram 8.8 m2
Theoretical coverage of 50 microns per liter 11 m2 / td>

Drying and coating conditions

Drying time Next layer application time
Temperature surface depth Complete hardening minimum Maximum Notes
25 ° C 4 hours 2 days 6 days 24 hours 7 days Other factors such as the thickness of the color film and temperature changes, etc. affect the drying time.

Terms and equipment of application

Thinner Alkyd Thinner
Application temperature 5 to 50 degrees Celsius
Maximum relative humidity 80%
Surface temperature 3 to 5 degrees above the dew point
Application method Air spray. Airless spray, brush and roll
Application conditions Ordinary spray Airless spray brush Roll
Percent solvent 7-10% 3-5% 5-7% 4-6%
head pressure 2 -5 times 140 – 160 bar
Nozzle head diameter 1.2 to 1.8 mm 0.3 to 0.5 mm
hand distance 30-50 cm 40-60 cm

Surface preparation

Painted surfaces – These surfaces must be completely clean and free of any grease and other contaminants. Before painting, the surface should be completely dry and if a long time has passed since the application of the undercoat, a suitable roughness should be created by soft sanding on the surface. Steel surfaces – Wash the steel surface with a suitable solvent to remove grease, salt and any other contaminants. De-rust and create profiles on surfaces by various methods such as sand blasting up to 2.5 degrees Swedish or by mechanical tools up to ISO-ST3 degree. In metal structures and welded points and corners should be smooth and polished and free of any appendages and sharpness. After de-rusting and creating the profile of the particles obtained from the preparation and other contaminants, remove them from the surface with a vacuum method free of moisture and grease and by vacuum method and thoroughly clean them. Note that the application of the first layer (primer) should be done no later than two hours after preparation. Concrete surfaces – If the concrete is fresh, it must be 28 days after the concrete has been applied (the concrete surface is completely dry). If the concrete is old, the surface must be washed with fresh water to remove contaminants such as salts, grease, dust and Dust, loose and unstable particles, etc. should be removed from its surface. It is recommended to use alkaline degreasers if necessary, especially in the case of old concretes, to remove all contaminants and to repeat the washing operation with water after degreasing. The mechanical method is created by the mechanical power tool suitable roughness on the surface

محصولات مشابه

عنوان

لورم ایپسوم متن ساختگی با تولید سادگی نامفهوم از صنعت چاپ و با استفاده از طراحان گرافیک است. چاپگرها و متون بلکه روزنامه و مجله در ستون و سطر آنچنان که لازم است.

عنوان

لورم ایپسوم متن ساختگی با تولید سادگی نامفهوم از صنعت چاپ و با استفاده از طراحان گرافیک است. چاپگرها و متون بلکه روزنامه و مجله در ستون و سطر آنچنان که لازم است.

عنوان

لورم ایپسوم متن ساختگی با تولید سادگی نامفهوم از صنعت چاپ و با استفاده از طراحان گرافیک است. چاپگرها و متون بلکه روزنامه و مجله در ستون و سطر آنچنان که لازم است.

عنوان

لورم ایپسوم متن ساختگی با تولید سادگی نامفهوم از صنعت چاپ و با استفاده از طراحان گرافیک است. چاپگرها و متون بلکه روزنامه و مجله در ستون و سطر آنچنان که لازم است.